Ranganathan Duraisamy

Surgical technologist by profession, blogging as a passion, and created blogs to educate juniors, other professionals in the field of Anaesthesia and surgery. https://surgicaltechie.com/ranganathan-duraisamys-message/

Vasectomy Male sterilization surgery

Vasectomy or male sterilization is the elective procedure for the removal of a section of vas deferens for permanent contraception. vasectomy side effects and vasectomy recovery The surgical procedure proceeds with small with cut the vas deferens and ligates both ends with suture or endo surgical unit. Anesthesia The procedure is done under the local

Vasectomy Male sterilization surgery Read More »

How to measure Blood Pressure in Anaethesia work station

How to Measure Blood Pressure, Non-Invasive Blood Pressure in Monitor for continuous monitoring, Blood pressure age chart, nibp cuffs, etc Preparation for NIBP monitoring : Place the patient In supine position and connect the BP cuff to the arm If the cuff not placed at the level of the heart than the pressure values obtained

How to measure Blood Pressure in Anaethesia work station Read More »

How to Measure ICP-Intracranial Pressure continuously

icp sensor

How to Measure ICP? 14 gauge Tuohy needle with stylet Microsensor ICP transducer with a depth marking Description Microsensor ICP transducer is a catheter with a microminiature silicon strain gauge type sensor mounted at one end and an electrical connector at the other end Sensing element made of strain gauge silicon micro clip and catheter

How to Measure ICP-Intracranial Pressure continuously Read More »

Sterilization of Equipments and cables

ot preparation

Using the recommended procedure, sterilize and degassed before use. The sterilizer temperature must not exceed 70° C (158° F) since plastics in the pressure transducer may deform or melt above this temperature. Cleaning and Sterilization for CO2 adapter Follow the cleaning and sterilization instructions listed below to clean or sterilize Capnostat and its accessories. Capnostat

Sterilization of Equipments and cables Read More »

New Technology in suture Manufacturing

New Technology in suture Manufacturing Nowadays using of the suture replaces by stapler or other skin closure materials. New invention comes, but suture remains its places The suture made of monofilament to reduce infection and tissue damage with the antibacterial coating etc. Many of the new innovation and technique using suture material for a better

New Technology in suture Manufacturing Read More »

How to measure spo2 level using Pulse oximeter

respiration

The monitor provides continuous, non-invasive, automatically calibrated measurements of both functional oxygen saturation of hemoglobin and pulse rate. The instrument combines the principles of spectrophotometric oximetry and plethysmography. It consists of an electro-optical sensor that applied to the patient and a microprocessor-based monitor that processes and displays the measurements. The electro-optical sensor contains two low-voltage,

How to measure spo2 level using Pulse oximeter Read More »

Polypectomy procedure using snare

Polyps with a diameter of up to 20 mm removed using a polypectomy snare. snare size and the clinical situation decide the procedures to proceed. The ENDO CUT  fractioned cutting mode ideally suited for removing the tumor in the gastrointestinal tract. Procedures as polypectomy and mucosa resection. The alternating cutting and coagulation intervals can adapt

Polypectomy procedure using snare Read More »

Cardiac output measurement

Cardiac output measurement important measure of cardiac performance. It measures the volume of blood pumped into the circulatory system by the heart per min. Cardiac output related to blood pressure. Several methods used for determining cardiac output. The method used by L&T patient monitoring system is the thermodilution method. With thermodilution, cardiac output measured as

Cardiac output measurement Read More »

Anesthesia Gas Monitoring

anaesthesia work station

Anesthesia Gas Monitoring Description: Measures CO2 and volatile anesthetic agents (Halothane, isoflurane, Sevoflurane, Enflurane, Desflurane. Mean alveolar concentration), RR & N20. CO2 and volatile anesthetics absorb infrared light. By means of a pump, a small quantity of the breathing gas drawn through a measuring vessel, which is penetrated by infrared light. With the aid of

Anesthesia Gas Monitoring Read More »