Equipment

Arthroscopy in Joint surgery | Surgical World

arthroscopy

ARTHROSCOPY surgery Console in Knee Joint surgery commonly performed minimally invasive procedure, where instruments are introduced into joints through a very small incision, enabling “key-hole” surgery. Used in the knee and elbow joint surgery in common Knee the most common Joint where arthroscopy is done, followed by the shoulder, but the ankle, hip, wrist, and

Arthroscopy in Joint surgery | Surgical World Read More »

How to sterilize the cable and Transducer ?

How to sterilize the cable and Transducer ?

Routine maintenance has been designed to operate continuously with proper maintenance procedures and periodical checking. In order to ensure better performance and safety, routine maintenance should be performed. How to sterilize the cable and Transducer? Leads, sensors, and probes should be carefully checked for any signs of damage. Damaged leads should be replaced. Do not

How to sterilize the cable and Transducer ? Read More »

How to measure Blood Pressure in Anaethesia work station

How to Measure Blood Pressure, Non-Invasive Blood Pressure in Monitor for continuous monitoring, Blood pressure age chart, nibp cuffs, etc Preparation for NIBP monitoring : Place the patient In supine position and connect the BP cuff to the arm If the cuff not placed at the level of the heart than the pressure values obtained

How to measure Blood Pressure in Anaethesia work station Read More »

How to Measure ICP-Intracranial Pressure continuously

icp sensor

How to Measure ICP? 14 gauge Tuohy needle with stylet Microsensor ICP transducer with a depth marking Description Microsensor ICP transducer is a catheter with a microminiature silicon strain gauge type sensor mounted at one end and an electrical connector at the other end Sensing element made of strain gauge silicon micro clip and catheter

How to Measure ICP-Intracranial Pressure continuously Read More »

Sterilization of Equipments and cables

ot preparation

Using the recommended procedure, sterilize and degassed before use. The sterilizer temperature must not exceed 70° C (158° F) since plastics in the pressure transducer may deform or melt above this temperature. Cleaning and Sterilization for CO2 adapter Follow the cleaning and sterilization instructions listed below to clean or sterilize Capnostat and its accessories. Capnostat

Sterilization of Equipments and cables Read More »

Endoscopic Mucosal Resection

endoscopy surgery

EMR is an endoscopic procedure for resecting sessile or flat lesions that, limit to the mucosa and submucosa. Usually, EMR is carried out in combination with supportive techniques, such as elevation or suction  EMR-Endoscopic Mucosal Resection  When high-pressure elevation using the flexible waterjet probe, fluid accumulates in the submucosa and forms a fluid cushion. This

Endoscopic Mucosal Resection Read More »

Capnography- End Tidal CO2 Measurement

capnographic waveform

ET CO2 Module measures carbon dioxide (Capnography) and respiratory rate with a unique solid-State sensor called a Capnostat. The Capnostat placed onto an Airway Adapter placed in the patient’s airway circuit typically between the ventilator elbow and the patient end. Capnogram measure of exhaled CO2 in the form of capnography waveform for capnographic purpose In

Capnography- End Tidal CO2 Measurement Read More »

Ultrasonography Uses and Doppler

doppler

Ultrasound scanning or Ultrasonography means exposing the parts of the body to high-frequency sound waves to produces the visual pictures of the internal structures of the body. What is Ultrasound? Using high-frequency sound in ultrasound for scanning the internal organs of human. The inaudible high-frequency sound waves are transmitted to the body tissue using the ultrasound

Ultrasonography Uses and Doppler Read More »

How to use Electrocardiograph ECG 12 lead placement

ecg

For continuous. stable ECG monitoring, not disturbed by the patient’s movement. How to measure ECG or EKG test with electrodes put on the patient’s chest. The following section describes various modified ecg 12 lead placement, which is similar to the standard 12 ECG leads.  Here you can know how to measure ECG An EKG test is

How to use Electrocardiograph ECG 12 lead placement Read More »