Medical Equipment

How to use ventilator with Type of modes

The ventilator provides complete life support for the patient with post-surgical and ARDS etc. Non-invasive ventilation intended for the use of positive airway pressure ventilation. see more for modes of ventilation in the post how to use ventilator Minimum tidal volume ventilation delivered  shall be equal to or greater than the 20 ml for adults

How to use ventilator with Type of modes Read More »

How to use Transducer in Blood Pressure Monitoring

Transducer

Blood Pressure monitoring in a patient using a transducer for various pressure values like Invasive blood pressure, central venous pressure, ICP, intraabdominal pressure, Esophageal pressure, gastric pressure, etc. check for calibration definition, transducer definition and blood pressure readings Step by Step Instruction Ensure that the cable compatibility with the equipment. Connect the reusable cable to

How to use Transducer in Blood Pressure Monitoring Read More »

Pressure cuff bag for IV Infusion

pressure cuff Bag

Pressure cuff Bag used to provide IV fluid or blood products spontaneously. It is available in the 1000ml and 500ml The pressure bag made of Polyvinyl chloride with a Pressure gauge and three-way stopcocks at the end inflating balloon will be present for giving pressure. Pressure cuff bag -Indication The pressure cuff indicated rapid fluid

Pressure cuff bag for IV Infusion Read More »

NIV Mask for Non Invasive Ventilation

mask

The Non vented facial mask is single use by a single patient. It is designed for patients for controlled non-invasive positive pressure ventilation. The mask should be used with ventilator equipment with an active exhalation valve with a respiratory flow sensor or respiratory circuit. The exhalation valve should be connected to a respiratory circuit in

NIV Mask for Non Invasive Ventilation Read More »

Intra abdominal pressure Monitoring using Manometer

Intra abdominal pressure

Intra abdominal pressure (lAP) device with transducers will help to find out the Intra abdominal pressure of the patients for a better understanding of physician. Indications Postoperative abdominal surgery Risk patient like intra abdominal hypertension Infusing fluid into a urinary bladder catheter. Measuring the hydrostatic pressure within the urinary bladder. Contraindications:  Urinary bladder rupture or

Intra abdominal pressure Monitoring using Manometer Read More »

Pressure Transducer

Pressure monitoring Transducer

These are general instructions for setting up a Pressure monitoring Transducer with the disposable pressure transducer. Since kit configurations and procedures vary according to hospital references, it is the responsibility of the hospital to determine exact policies and procedures. For single use only Caution: The use of lipids with the disposable pressure transducer may compromise product

Pressure Transducer Read More »