Anesthesia

How to use Transducer in Blood Pressure Monitoring

Transducer

Blood Pressure monitoring in a patient using a transducer for various pressure values like Invasive blood pressure, central venous pressure, ICP, intraabdominal pressure, Esophageal pressure, gastric pressure, etc. check for calibration definition, transducer definition and blood pressure readings Step by Step Instruction Ensure that the cable compatibility with the equipment. Connect the reusable cable to

How to use Transducer in Blood Pressure Monitoring Read More »

Pressure cuff bag for IV Infusion

pressure cuff Bag

Pressure cuff Bag used to provide IV fluid or blood products spontaneously. It is available in the 1000ml and 500ml The pressure bag made of Polyvinyl chloride with a Pressure gauge and three-way stopcocks at the end inflating balloon will be present for giving pressure. Pressure cuff bag -Indication The pressure cuff indicated rapid fluid

Pressure cuff bag for IV Infusion Read More »

NIV Mask for Non Invasive Ventilation

mask

The Non vented facial mask is single use by a single patient. It is designed for patients for controlled non-invasive positive pressure ventilation. The mask should be used with ventilator equipment with an active exhalation valve with a respiratory flow sensor or respiratory circuit. The exhalation valve should be connected to a respiratory circuit in

NIV Mask for Non Invasive Ventilation Read More »

Pressure Transducer

Pressure monitoring Transducer

These are general instructions for setting up a Pressure monitoring Transducer with the disposable pressure transducer. Since kit configurations and procedures vary according to hospital references, it is the responsibility of the hospital to determine exact policies and procedures. For single use only Caution: The use of lipids with the disposable pressure transducer may compromise product

Pressure Transducer Read More »

Tumescent Anesthesia

Tumescent Anesthesia

Tumescent local anesthesia playing the main part in the cosmetic and dermatological procedures. It has epinephrine that reduces the blood flow by its action of vasoconstrictors and makes the tissue swell by itself after injecting. solution helps the surgeon to operate without any pain, less risk, and blood loss. know more about the tumescent definition

Tumescent Anesthesia Read More »

How to use Closed suction system in ICU

Closed suction system

The closed suction system above the cuff of the tracheal tube. Suction in intubated patients, suction in ventilated patients etc Instruction for use and Indication Continuous ventilation. To reduce the risk of hypoventilation and hypoxia, Low expiratory tidal volume. The device consists of the sterile catheter for the suctioning enclosed with the sterile polyethylene cover.

How to use Closed suction system in ICU Read More »

Pulse oximeter life saving Basic Equipment

Sensors type

It essentially consists of a probe with two light emitting diodes and a photodetector and a microprocessor. Pulse oximetry is a standard non-invasive method for monitoring of arterial blood O2 saturation at the level of arterioles using Pulse oximeter. It is a simple, continuous measurement of oxygen saturation, accurate, dependable, convenient and rapid method using types

Pulse oximeter life saving Basic Equipment Read More »

CVP-Central venous catheter Placement using seldinger’s techniques

cvp

The procedure mainly used for the continuous central venous pressure CVP monitoring and for purpose of the fluid management, drug therapy, etc. central venous catheter is placed either in the internal jugular vein or subclavian vein, femoral vein, axillary vein. CVP Indication Infusion and fluid volume therapy Patients requiring CVC for Hemodynamic monitoring Administration of

CVP-Central venous catheter Placement using seldinger’s techniques Read More »